The information presented in this cross reference is based on TOSHIBA's selection criteria and should be treated as a suggestion only. Please carefully review the latest versions of all relevant information on the TOSHIBA products, including without limitation data sheets and validate all operating parameters of the TOSHIBA products to ensure that the suggested TOSHIBA products are truly compatible with your design and application.Please note that this cross reference is based on TOSHIBA's estimate of compatibility with other manufacturers' products, based on other manufacturers' published data, at the time the data was collected.TOSHIBA is not responsible for any incorrect or incomplete information. Information is subject to change at any time without notice.
请输入3个以上字符
缓冲器型产品和总线开关型产品的工作频率计算方法不同。缓冲器型产品可以根据负载和导通电阻的CR值获得的传输延迟时间来计算。然而,总线开关型产品可以根据负载和导通电阻CR时间常数进行计算。
下面简要介绍一下各自的计算方法:
以开关I/O电容(CI/O)为14pF的TC7SPB9306为例。假设负载电容(CL)为30pF,上拉电阻(Rpu)的电阻值为1kΩ。然后,按下式计算τ:
τ=(14pF+30pF)×1kΩ
因此,最大工作频率的大致计算值为20MHz。
该计算的结果仅应作为数据表中所示条件下的估计值。
应充分评估电平转换器,以确保其能在实际工作条件下正常工作,因为其传输延迟时间随电路板电容和其它条件相应变化。