This webpage doesn't work with Internet Explorer. Please use the latest version of Google Chrome, Microsoft Edge, Mozilla Firefox or Safari.
请输入3个以上字符
The information presented in this cross reference is based on TOSHIBA's selection criteria and should be treated as a suggestion only. Please carefully review the latest versions of all relevant information on the TOSHIBA products, including without limitation data sheets and validate all operating parameters of the TOSHIBA products to ensure that the suggested TOSHIBA products are truly compatible with your design and application.
Please note that this cross reference is based on TOSHIBA's estimate of compatibility with other manufacturers' products, based on other manufacturers' published data, at the time the data was collected.
TOSHIBA is not responsible for any incorrect or incomplete information. Information is subject to change at any time without notice.
请输入3个以上字符
什么是掉电保护?
为降低功耗,具有两个电压范围(VCC1和VCC2)的系统可以提供局部掉电模式,其中由VCC1运行的子系统将被关闭。例如,假设在电压范围VCC1内使用74VHC系列。74VHC系列在输出端和电源之间具有意外的寄生二极管。因此,当VCC2>VCC1时,该寄生二极管导通。在这种情况下,产生的大电流可能会损坏IC。使用既没有输入也没有输出寄生二极管的IC(例如74VHCT、74LCX和74VCX系列)可以防止器件损坏。
这些系列提供掉电保护。
很容易区分一个IC是否具有掉电保护功能。
让我们看一下74VHC和74LCX系列IC的数据表。
参见直流特性表。
74LCX245的数据手册中指定了断电漏电流(IOFF),这表明即使在电源关闭时也几乎没有漏电流流动。
因此,74LCX245具有掉电保护功能。
相反,由于74VHC245在输出端和电源之间有一个寄生二极管,如果在相同条件下进行测试,则会有大电流流过。
因此,74VHC245没有IOFF调节,也没有掉电保护功能。
注:以下四个系列提供掉电保护功能:
•74VHCT系列 •74VHCV系列
•74LCX系列 •74VCX系列
对于74VHCT系列,掉电保护由IOPD和IIN指定,而不是由IOFF指定。