The information presented in this cross reference is based on TOSHIBA's selection criteria and should be treated as a suggestion only. Please carefully review the latest versions of all relevant information on the TOSHIBA products, including without limitation data sheets and validate all operating parameters of the TOSHIBA products to ensure that the suggested TOSHIBA products are truly compatible with your design and application.
Please note that this cross reference is based on TOSHIBA's estimate of compatibility with other manufacturers' products, based on other manufacturers' published data, at the time the data was collected.
TOSHIBA is not responsible for any incorrect or incomplete information. Information is subject to change at any time without notice.
请输入3个以上字符
对于工业应用中使用的逆变器系统,国际标准IEC 61800-5-1《可调速电力驱动系统——安全要求》[注1]中规定了与隔离相关的指标。工业用通用逆变器的主要系统电压范围为200V至600V。以600V系统为例,过压类别为Ⅲ[注2]时所需的冲击电压为6kV,而一级以上8kV则需要设计加强隔离。
对于DCL54x01系列,我们针对VDE V 0884-11标准的最大工作隔离电压VIORM=1.0kVrms采用了加强隔离[注3]。该标准的加强隔离要求的冲击电压为12.8kV[注4],产品设计中加入了满足此要求的电阻。因此,其具有足够的冲击电压容限,适用于工业应用中的各种通用用途。
[注1]请购买标准文件并查看规格。
[注2]请参考应用说明:光耦安全标准(773.7KB)
[注3]截止2023年3月,DCL541L01、DCL541H01、DCL542L01和DCL542H01的VDE批准仍在办理之中。
[注4]最大工作隔离电压VIORM=1.0kVrms。III类过压对应的冲击电压为8kV。VDE V 0884-11要求安全系数为加强隔离冲击电压的1.6倍。因此,要求1.6×8kV=12.8kV。